Loading...
TE-WILBUR OPERATIONS MANUAL REV 002.15 06/11/2015
Tisch Environmental 1-TSP-AND-PM10 sales@tisch-env.com www.tisch-env.com Page 165 of 183
MODBUS
Address
Comm
Frame
Data
Type
TE-Wilbur
Internal
Address
Description
413069
330C
Float32
D13068
Flow CV
413071
330E
Float32
D13070
Sample Time
413073
3310
BIN32
D13072
Filter ID
413075
3312
BIN32
D13074
Site ID
413077
3314
BIN32
D13076
Serial Number
413079
3316
Float32
D13078
Instantaneous Flow Reading
413081
3318
Float32
D13080
Instantaneous Baro Pressure Reading
413083
331A
Float32
D13082
Instantaneous Filter Temp Reading
413085
331C
Float32
D13084
Instantaneous Ambient Temp Reading
413087
331E
Float32
D13086
Instantaneous System Pressure Reading
002604
0A2B
Binary
M2003
10% Flow Variance Alarm
002606
0A2D
Binary
M2005
High Pressure Alarm
002616
0A37
Binary
M2017
5% Flow Variance Alarm
002617
0A37
Binary
M2020
Sample time <23 or >25 hours
002612
0A33
Binary
M2013
Ambient Temperature Failure
002613
0A343
Binary
M2014
Filter Temperature Failure
002609
0A30
Binary
M2010
Flowmeter Failure
002611
0A32
Binary
M2012
Barometric Pressure Failure
002610
0A31
Binary
M2011
Pressure Sensor Failure
002627
0A42
Binary
M2032
Temperature Variance Alarm
002628
0A43
Binary
M2033
Sample Warning Alarm
002630
0A45
Binary
M2035
Battery Discharge Alarm
002631
0A46
Binary
M2036
Battery Failure Alarm
001512
05E7
Binary
M0637
Shut Down Sample Alarm
001529
05F8
Binary
M0660
Screen Battery Failure
001652
0673
M0813
Power Fail
001772
06EB
M0963
Mains Power Lost
001497
05D8
Binary
M0620
Custom Sample Set
001501
05DC
Binary
M0624
1 in 3 Sample Set
001502
05DD
Binary
M0625
1 in 6 Sample Set
001503
05DE
Binary
M0626
1 in 12 Sample Set
001500
05DB
M0623
Sample Running