Loading...
TE-WILBUR OPERATIONS MANUAL REV 002.15 06/11/2015
Tisch Environmental 1-TSP-AND-PM10 sales@tisch-env.com www.tisch-env.com Page 172 of 183
Appendix B: Drawings
Appendix B includes detailed drawings on the TE-Wilbur sampler.
B.1 Electrical Terminal TB1 connections
Terminal
Number
Description
1
(+) terminal for LED lighting strips Blue/Green wire
2
(+) terminal for ventilation fan Brown wire
3
(+) terminal for solenoid valve
4
black wire (+) signal output from flowmeter
5
brown wire (+) supply voltage to flowmeter
6
blue wire (-) supply voltage to flowmeter
7
(+) Supply and signal to pressure sensor
8
(-) supply and signal to pressure sensor
9
white wire (+) signal from barometric pressure sensor
10
black wire (-) supply to barometric pressure sensor
11
red wire (+) supply to barometric pressure sensor
12
(+) signal for pump speed control
13
(-) signal for pump speed control
14
ambient temperature connection (no polarity)
15
ambient temperature connection (no polarity)
16
filter temperature connection (no polarity)
17
filter temperature connection (no polarity)
18
(+) connection for battery pack
19
(-) connection for battery pack
Loading...
Terms of Use | Privacy Policy | DMCA Policy