Loading...
`Miscellaneous Settings
&Max Link Speed
Allows you to set the operation mode of the PCI Express slots to Gen 1, Gen 2, or Gen 3. Actual operation
Auto

&3DMark01 Enhancement
 
`Smart Fan 5 Settings
&Monitor
 
&Fan Speed Control
Allows you to determine whether to enable the fan speed control function and adjust the fan speed.
Normal Allows the fan to run at different speeds according to the temperature. You can adjust
the fan speed with System Information Viewer based on your system requirements.

Silent Allows the fan to run at slow speeds.
Manual Allows you to control the fan speed in the curve graph.
Full Speed Allows the fan to run at full speeds.
&Fan Control Use Temperature Input
Allows you to select the reference temperature for fan speed control.
&Temperature Interval
Allows you to select the temperature interval for fan speed change.
&Fan/Pump Control Mode
Auto Lets the BIOS automatically detect the type of fan/pump installed and sets the optimal

Voltage Voltage mode is recommended for a 3-pin fan/pump.
   
&Fan/Pump Stop
Enables or disables the fan/pump stop function. You can set the temperature limit using the temperature

&Temperature
 
&Fan Speed
 
&Flow Rate
 
&Temperature Warning Control
  
oC/140oF, 70oC/158oF, 80oC/176oF, 90oC/194oF.
&Fan/Pump Fail Warning
Allows the system to emit warning sound if the fan/pump is not connected or fails. Check the fan/pump

- 27 -
Loading...
Terms of Use | Privacy Policy | DMCA Policy
2006-2020 Rsmanuals.com