Loading...
TE-1000 PUF 28 Operations Manual
Troubleshooting
*note: this is a general troubleshooting guide, not all problem may apply to every
sampler*
Problem
Solution
Brush Motor Won’t Turn On
-Check Motor brushes(Change every 500 hours)
-Check Motor(Should be replaced after 2 brush changes
about 1500 hours)
-Check power supply
-Ensure that all electrical connections are secure
-Make sure timer is on
-Make sure flow controller(if applicable) is adjusted
properly
-Check for loose or damaged wires
-Check speed on TE-5010, ensure adjustment screw is
turned clockwise to increase motor speed.
Brushless Motor Won’t Turn
On
-Ensure that all electrical connections are secure
-Make sure flow controller(if applicable) is adjusted
properly
-Check power supply
-Make sure timer is on
-Check for loose or damaged wires
Mechanical timer not working
-Make sure trippers are set properly
-Make sure that trippers are not pressed against switch at
start up, the timer need to rotate a few degrees before the
trippers hit the switch
-Check for loose or damages wires
-Check power supply
-Check electrical hook up diagram to ensure correct
installation
-Check Motor
Digital timer not working
-Check timer settings
-Make sure current date and time are correct
-Make sure power cords are properly connected
-Check fuse on main PC board (F3)
-Check Power Supply
-Check Motor
Loading...
Terms of Use | Privacy Policy | DMCA Policy