TE-5000D TSP 35 Operations Manual
11. Replace blower motor flange on top of motor making sure to center gasket.
Assemble together with filter holder. Lower filter holder and blower motor
down through top support pan on shelter.
**IMPORTANT** To enhance motor life:
Change brushes before brush shunt touches armature.
Seat new brushes by applying 50% voltage for 10 to 15 minutes, the TE-5075
brush break in device allows for the 50% voltage.
TE-116311
110v MFC Motor
TE-33384
110v MFC Motor Brush(Green)
TE-116312
220v MFC Motor
TE-33378
220v MFC Motor Brush(Brown)