TE-PNY1123 34 Operations Manual
Motor Brush Replacement
110 volt (Brush part #TE-33384)
220 volt (Brush part #TE-33378)
CAUTION: Unplug the unit from any line voltage sources before any servicing
of blower motor assembly.
The following steps are accompanied by pictures to aid your
understanding of motor brush replacement procedures. Please be
aware that the pictures are standardized and may not match the
equipment that you are using. Motor brush removal and replacement
does not change based on motor or brush type, so do not be confused if
your equipment differs from what is pictured.
1. Remove the motor mounting cover by removing the four bolts. This will
expose the flange gasket and the motor. Turn motor over.
2. Remove ground wires from backplate and carefully lift the metal housing
from the motor.
3. With a screwdriver, carefully remove the plastic fan cover by prying in
between the brush and cover until both sides pop loose.
4. With a screwdriver, carefully pry the brass quick disconnect tabs away from
the expended brushes.