Maintenance and Care
A regular maintenance schedule will allow a monitoring network to operate for longer
periods of time without system failure. Our customers may find that the adjustments in
routine maintenance frequencies are necessary due to the operational demands on
their sampler(s). We recommend that the following cleaning and maintenance
activities be observed until a stable operating history of the sampler has been
established.
TE-5170D-V VFC TSP Sampler
1. Make sure all gaskets (including motor cushion) are in good shape and that they
seal properly.
2. The power cords should be checked for good connections and for cracks (replace
if necessary).
CAUTION: DO NOT allow power cord or outlets to be immersed in water!
3. Inspect the filter screen and remove any foreign deposits.
4. Inspect the filter holder frame gasket each sample period and make sure of an
airtight seal.
5. Check or replace motor brushes every 300 to 400 running hours.
6. Make sure elapsed time indicator is working properly.