Display Operations
Owner’s Manual
18
SETUP menu
This shows the current values for various setup parameters of this unit.
Selecting a setup item
You can select setup items by pressing the (DEC) button or (INC) button. The parameter value of the selected item
is highlighted. The highlighted indication disappears when 10 seconds have elapsed without any front panel operation
being performed. You can switch screens by long-pressing the (DEC) button or (INC) button.
Setting a parameter value
By turning the encoder with switch, you can select the parameter value of the selected item. If the value is changed, the
display area of the currently selected parameter flashes. When you press the encoder, the setting is actually specified, and
the flashing stops. If you move the cursor while the parameter display area is flashing, the change is discarded and the
flashing also stops. In the same way, if you switch the menu selection while the parameter display area is flashing, the
change is discarded.
Table of parameters
The following table shows the items that can be selected, the description of the parameters, and the values that can be
specified (* is the default value).
Item/parameter Description Values
UNIT ID Specifies the ID of the unit. Y000(0)–Y07F(127)
Y001*
START UP MODE Selects the HA parameter settings at start-up. This setting is applied the
next time the unit starts up.
If you plan to connect an Rio-native device, such as a CL series product,
set the switches to [REFRESH]. The Rio will not input or output audio
until the connected Rio-native device transmits its settings to the Rio, so
that the Rio will not output audio accidentally.
REFRESH:
Initializes a portion of the internal memory when starting up.
However, MUTE is ON.
RESUME:
Starts up in the state prior to the most recent power-off.
However, MUTE is OFF.
REFRESH w/o MUTE
Initializes a portion of the internal memory when starting up. The
initial values are the same as for REFRESH.
However, MUTE is OFF.
REFRESH*,
RESUME,
REFRESH w/o MUTE
HA GAIN –6 dB
+48V OFF
HPF OFF
HPF FREQ 80.0 Hz
GAIN COMPENSATION OFF
COMPENSATION GAIN –6 dB