Installation
SensorInstallation
10
X63/X63i/X62/X33/X32InstallationandCalibrationManual P/N:70100697
TS-i3 Sensor Installation
EachTSi3sensorcontainsasingleordualaxissensorelement,andwillbedifferentdependingon
wheretheyaremounted.Sensorsmountedonthestick,boomandbucketaresingleaxis,andareonly
mountedinaleftorrightorientation.Thesensormountedonthebodyisdualaxis,andismounted
onlywithaleft,right,orflatorientation.
Wheninstallingthesensors,ensurethattheyaremountedparalleltotheaxisbeingmeasuredwith
thedirectionarrowpointingawayfromthecab(Figure13).Locatesurfacesthatprotectthesensor
fromphysicaldamageandareconvenientforcablerouting.Whenthepositionoftheimplementisat
zerodegrees(horizontal),makeanoteofthedirectionofthearrowmarkerontheseriallabel(located
onthetopofthesensor).Thisdirectionisneededduringcalibration.Thecalibrationprocessuses3D
MCtoenterdirection,orientation,andothersensorvariables.
TS-i3 Sensor Orientation
Figure13:TSi3SensorLocationandDirection
Direction
of Travel
Left
Back
Right
Mountingeachtiltsensorwithin+/‐20°ofthepivotcenterlineisagoodpractice.Thoughnot
necessaryforsystemperformance,squaringthesensorstoeachpartofthemachinemakesfora
cleanerlookinginstallation.
Alltiltsensororientationisdeterminedwhentheimplementishorizontal(zerodegrees).The
orientationofeachtiltsensorisenteredin3DMC.