Installation
SensorInstallation
15
X63/X63i/X62/X33/X32InstallationandCalibrationManual P/N:70100697
Boom Sensor Mounting
Fortheboomsensor,locateaconvenientsurfaceparalleltotheboomcenter.Therecommendedmounting
locationisup,onthetopoftheboom,withthearrowpointingforwardtowardthedirectionoftravel
(Figure18).
Ifmountingonthesideoftheboom,becausemanyboomswilltaperoutattheboompivot,besure
toplacethesensoratalocationawayfromtheboompivot

Figure18:BoomSensorMounting
Placingtheboomsensoronataperedsectionwillcausecalculationerrors.
TSi3sensorsareonlymountedontheleftorrightoftheboom.
CL
Correct
Up Location
(Recommended)
CL
Correct
Side Location
CL
Incorrect Taper Location
Direction of Travel