Calibration
MachineCalibration
30
X63/X63i/X62/X33/X32InstallationandCalibrationManual P/N:70100697
5. TapSetnexttoPitch,enterthePitchvalueas‐90.0°,andtapSetagain(Figure35).
Figure35:SetPitchValueto‐90.0
6. TapOKtocontinue.
7. TocorrectlysettheRoll,movethestickupintheairuntilthePitchreadszero(0.0°)(Figure36).
Figure36:Pitch0.0°
8. TapSetnexttoRoll,enterthestickrollvaluetomatchthebodyrollvalue,andtapSet
again.(Figure37);tapOKtocontinue.
Figure37:SetStickRollValuetoMatchBodyRollValue
IfthebodyPitchandRollvalueshavenotchangedfromwhenthebodysensorwascalibrated,
entertherecordedbodyRollvalueforthestickRollvalue.Ifthebodypitchandrollhaschanged,
navigatetothebodysensorandrecordthenewbodyRollvalue,andenterthatnewvaluefor
thestickRollvalue.