CAN Termination
Toensurepropercommunicationbetweenthesensorsandthecontrolbox,thelastsensorphysically
connectedmustusethehardterminatorprovidedwiththeexcavatorsystems.Typically,thishard
terminatorconnectstothebucketsensor(orthedogboneandtiltbucketsensors).
Figure55:HardTerminatoronSensorFurthestfromtheDisplay
Sensor Filtering
Thefilterlevelforeachsensorcanbechangeddependingontheapplicationandoperator’schoice.Avalue
of4(heavyfiltering)willdampensensorreaction,whileavalueof1(lightfiltering)willcausefastersensor
reaction.Thedefaultfilterlevelis2.NotethatforTSi3sensors,orientationwillonlybeleftandright.
1. In3DMC,tapTopconMenuButtonControlMachinesetup.Selecttheapplicablemachine
fileandtapEdit.TapNexttonavigatetothemachineelementsensorscreen.
2. TaptheWrenchiconnexttoSensorID(bucket)(Figure56).
3. SelectafilteringlevelandtapOK(Figure56).
4. NavigatethroughtheremainingstepsofMachineSetup,thensavethefileandexit3DMC.
Figure56:SetFilteringLevel(BucketSensor)
BODY BOOM STICK BUCKET
SENSOR
TERMINATOR
Donotusethe3DMCsoftwaretoterminateanysensor.Useonlythehardterminator.