Loading...
LS-B10W Laser Receiver Setup

43
X63/X63i/X62/X33/X32InstallationandCalibrationManual P/N:70100697
LS-B10W Calibration
TocalibratetheLSB10WLaserReceiver,determinethepositionofthereceiveronthestick.After
calibratingthesensor,3DMCwilldeterminetheangleoftheLSB10Wtothestickcenterline.
1. Positionthemachineonastablesurfacefreeofobstructions,androtatethebodyto0.0°roll.
2. OrientthesticksothattheLSB10Wispositionedvertically.
3. In3DMC,tapTopconMenuButtonControlMachinesetup.Selecttheapplicablemachine
fileforthejobandtapEdit.TapNexttonavigatetotheLaserReceiver(LSB10W)screen.
4. EnterthefollowingmeasurementsfortheLSB10W(Figure58).
Depthtocenterofstick
enterthemeasurementforthedistancebetweenthemiddleofthestick
tothelightcellsontheLSB10W.
Frombucketpivot
enterthemeasurementforthedistancefromthealongtheprojectedline
betweenthebucketpivotandstickpivotatthepointwheretheLSB10Wisperpendiculartothe
projectedline(
Figure58).
Leftofpivotline
enterthemeasurementforthedistancebetweenthemarkontheLSB10Wand
thepivotline.Ifrightofpivotline,useanegativevalue.
5. MakesuretheLSB10WLaserReceiverisvertical,andthentapCalibratetodeterminetheangle
betweenthestickandtheLSB10W(Figure58).
Figure58:LSB10WLaserReceiverMeasurements
Ifthesticksensorisreplacedwithanewtiltsensor,youmustrecalibratetheLSB10WLaserReceiver.
TotesttheLSB10Wcalibration,see“LSB10WTest ”onpage63.