Loading...
Verifying Setup

48
X63/X63i/X62/X33/X32InstallationandCalibrationManual P/N:70100697
String Line Verification
Setup
1. SetaZeroSlopeusingalaser.
2. Setupastringlinethelengthofthemachine’sreach,andthensetupthestringlevel.
3. EnsurethatyourmachineconfigurationissetupforGPSand2Din3DMC(Figure66).
4. TapTopconMenuButtonControl3D/2DControl2Dtoplacethemachineinto2Dmode
(Figure66).
Figure66:MachineSetupforStringLineVerification
5. Createaflatplanesurfacein3DMC.
Test
1. Extendthemachineimplementssothatthebucketisatthefarendofthestringline.
2. Lowerthebuckettothestring,andzerothebucketin3DMC.
3. Positionthebucketonthestringatseveralpoints,andcomparetheelevationreadingsshownin
3DMC;elevationreadingsshouldbezeroforeachposition(Figure62).
Figure67:MovetheBucketandCompare3DMCMeasurements
4. Ifthemeasurementsreadzerofrompointtopoint,thetestisdone.Iftheydonot,see
“Troubleshooting”onpage49.
Reasonableaccuracyiswithin0.10´.Ifthemachineiswellmaintainedandthe
measurementsmadewithinthisguideareprecise,accuracyshouldbeevenbetter.
Loading...
Terms of Use | Privacy Policy | DMCA Policy
2006-2020 Rsmanuals.com