Loading...
Verifying Setup

49
X63/X63i/X62/X33/X32InstallationandCalibrationManual P/N:70100697
Troubleshooting
Whentroubleshooting,beginwiththebucketsensors.Ifyouareunabletodeterminetheproblem,
proceedwiththesticksensor,andthentheboomsensor.Notethatforthebucketandboomsensors,there
areoptionalsecondarysensorsthatshouldbecheckediftheyareused.Ifyouareunabletodeterminethe
problemafterfollowingtheproceduresbelow,contactTopconsupport.
Troubleshooting the Bucket Sensor
1. Positionthebucketabovethestringlinesothatthebucketteethoredgeareattheirclosest
pointtothestring.
2. Placethebucketteethoredgeonthestring,andzerothebucketin3DMC.
3. Curlonlythebucketinandoutinvariouspositions,andmeasurethedistancefromthestring
linetothebucketteethawithmeasuringtape(Figure63).
Figure68:StringLineVerification‐Bucket
4. Comparethemeasuringtapevalueswiththoseshownin3DMC.
5. Ifthemeasurementscomparedagainst3DMCmatch,therecouldbeanissuewithoneofthe
othersensors;repeatsteps14andreverify.
6. Ifthemeasurementscomparedagainst3DMCstillmatch,checkthetiltbucketsensor(ifused),
andthenfollowthestepsin“TroubleshootingtheStickSensor”below.
7. Ifthemeasurementscomparedagainst3DMCdonotmatch,eachsensormustbeevaluatedfor
machinemeasurementorcalibrationerrors.
Troubleshooting the Stick Sensor
1. Positionthebucketabovethestringlinesothatthebucketteethoredgeareattheirclosest
pointtothestring.
2. Placethebucketteethoredgeonthestring,andzerothebucketin3DMC.
3. Curlonlythestickinandoutatvariouspositions,andmeasurethedistancefromthestringline
tothebucketteethwithameasuringtape(Figure69).