Loading...
Verifying Setup

54
X63/X63i/X62/X33/X32InstallationandCalibrationManual P/N:70100697
Method B: Measuring to a hub at 180°
Beforeyoubegin,ensurethatallequipmentandmeasurementsareusingthesameunitsofmeasure(i.e.
Meters,SurveyFeet,etc.).
RecordMeasurements:
1. Positionthemachineonaflatandstablesurface,andplaceahubinaflatopenarea.
2. Using3DMCasareference(inalocalizedproject),taptheElevationControlKey,theleftGPS
info...button,andthentapthePositiontab.
3. Positionthemachinedirectlynorth.BothbucketedgeswillhavethesameNorthingvalue
(Figure72onpage52).
4. Extendthemachineelementstotheirfullestreach,andloweronebucketcornertothehub.
5. RecordtheNorthingvalueofoneofthebucketcorners(e.gNorthingN=4720.25).
6. Raiseonlytheboom,movethemachineforwardbeyondthehub,androtatethemachinebody
180°tofacedirectlysouth.
7. Usingthesamebucketcornerchoseninstep5,placethecorneronthehubandrecordthe
Northingvalue(e.g.NorthingS=4720.45).
8. CalculatethedifferenceinNorthingvalues(e.g.NorthingDIFF=NorthingN‐NorthingS=‐0.20).
CalculateAdjustments:
Usethefollowingequationtodeterminetherequiredadjustment:
Adjustment=[Northing
DIFF
/2](seeTable5).
1. Adjustthevaluein3DMCforboththeMainandAuxantennasbythecalculatedamount.
2. RepeatallstepsofMethodBtoverifythecorrection.
Table5.MeasureExtendedPositionsExampleCalculation
Measurement Symbol Value Adjustment
HubNorthing(FacingNorth) NorthingN4720.25
HubNorthing(FacingSouth) NorthingS4725.45
NorthingDifference NorthingDIFF 0.20
[0.20/2]=‐0.10
Positiveadjustmentsshouldbeaddedtothe3DMCvalues,andnegativeadjustments
shouldbesubtracted.
FailuretoadjusttheAuxAntennavaluewillresultinarotationalerror.Donotphysicallymove