Full System Test

69
X63/X63i/X62/X33/X32InstallationandCalibrationManual P/N:70100697
Testing Machine Body Sensor for Accuracy
Testingthesensoronthebodyrequirescomparingthehubpositionwiththemachinetiltedatacrossslope
(Figure81).
1. Positionthemachineonacrossslopeatapproximately5%.
2. Placethecenterofthebucketonahubandrecordtheposition.
3. Rotatethemachine90degrees,andplacethecenterofthebucketonthesamehub.
4. Recordthenewposition,andthensubtractthetwopositionsfromeachother.
5. Thedifferencebetweenpositionsshouldbewithin+/‐0.2Ft.
Figure81:CheckCrossSlopeAccuracy
N E Z
MachineonCrossSlope
Position1
Position2
Differences
Machine on 5%
cross slope
Position 1
Position 2
Position 1 Position 2