Loading...
Specifications
ST-3 (P-32+ System Only)
113
P-32+ and P-32 Operator’s Manual P/ N: 1001547-01
ST-3 (P-32+ System Only)
Pulse Width Modulated
Proportional Mode
1-13, 225-1950 Hz programmable
Programmable dither 0-105 Hz, 0-15%
Programmable current limit
Sink or source operation
Solenoid (On/ Off) Mode 1-13, 225-1950 Hz programmable
Programmable dither 0-105 Hz, 0-15%
Programmable current limit
Sink or source operation
Danfoss
Proportional Mode
50% available voltage as neutral
> 50% = Raise, < 50% = Lower
Programmable dither 0-105 Hz, 0-15
Table 3. GC-35 Specifications
Table 4. GC-35 Specifications
Electrical
Resolut ion .0025 ft
Supply Voltage 10-32 VDC
Supply Current 300mA typical operating current
Emissions FCC Part 15, Subpart B Class A/ CI SPR 11I SO 13766/ EN 13309
Immunity ISO 13766 for radiated RF immunity and ESD
Transducer Frequency 50kHz burst
Ta r g e t Ran g e 14 in to 36 in
Detection Zone 9 in x 6 in at 2 ft - Stringline mode
8 in x 6 in at 2 ft - Surface mode
Physical
Display LEDs 1 ea. Status
11 ea. Left/ Right/ Centered - Stringline mode
Raise/Lower/ Ongrade - Surface mode
Housing Powder coated cast aluminum
Switches 1 ea sealed 32 position rotary encoder w/ gold contacts
7 ea momentary push button, elastomer over stainless domes
1 ea sealed latching push button (power)
Connector 11 pin bayonet/ shell size 18
Weight 3.0 lbs
Environmental
Operating Temperature C to + 80°C (32°F to 176°F)
Storage Temperature -40° C to 100°C (-40°F to 212°F)
Loading...
Terms of Use | Privacy Policy | DMCA Policy
2006-2020 Rsmanuals.com