Loading...
GC-35 Control Box Features and Setup
Control Box Features
23
P-32+ and P-32 Operator’s Manual P/N: 1001547-01
Grade Adjustment Direction Arrows
The Grade Adjustment Direction Arrows are located at the upper left and upper right of the Grade Adjustment
Knob.
When your Topcon P-32+ or P-32 System is set to Manual control, the Grade Adjustment Direction Arrow s
(Figure 39) light up in red to indicate the direction to turn the knob to reach On-Grade.
Figure 39: Grade Adjustment Direction Arrow s
Grade Adjustment LEDs
The Grade Adjustment LEDs (Figure 40) indicate raise, On-Grade, and lower information and corrections. See
Ta b l e 1 for a description of the Grade Adjustment LED indications.
Figure 40: Grade Adjustment LEDs
Ta b l e 1 describes grade adjustment LED indications. The values listed in Ta b l e 1 are default factory values.
Rotate Knob
Counterclockwise
To Reach Grade
Rotate Knob
Clockwise To
Reach Grade
Table 1. LED I ndications for Elevation/ Slope Control
LED Display LED Elevation Description Slope Description
Slowly blinking, yellow down
arrow
Outside of Working Window; beyond
0.2 ft above grade (no valve control)
Outside of Working Window;
beyond 2% above grade
Solid yellow down arrow Above grade; between 0.05 ft and .2 ft Above grade, between 1% and
2%
Blinking yellow down arrow Above grade; between 0.02 ft and .05 ft Above grade, between 0.5%
and 1%
Blinking yellow down arrow
w/ green bar
Within 0.02 ft of grade Within 0.5% of grade
Blinking green bar On grade On grade
Blinking red up arrow w/
green bar
Within 0.02 ft of grade Within 0.5% of grade
Blinking red up arrow Below grade; between 0.02 ft and 0.05
ft
Below grade, between 0.5%
and 1%
Solid red up arrow Below grade; between 0.05 ft and 0.2 ft Below grade, between 1% and
2%
Slowly blinking red up arrow Outside of Working Window; beyond
0.2 ft below grade (no valve control)
Outside of Working Window;
beyond 2% below grade