Getting Ready to Pave
Control Box Setup for Slope Control
72
P-32+ and P-32 Operator’s Manual P/ N: 1001547-01
Control Box Setup for Slope Control
The Slope Sensor should already be mounted on the transverse beam of the paver. The sensor can talk to both
Slope Sensores, but only one at a time. The sensor communicates to the Control Box through the cable.
To pave using slope control you must first calibrate the Slope Sensor, to the screed.
1. Find a smooth area where the screed can rest evenly across its entire surface. Using a laser, a Smart Level,
or a slope board, that itself has been calibrated, check the slope and direction of fall of the ground
(Figure 126).
Figure 126: Checking Slope
2. Place the screed on the ground and null it out.
3. With the Control Box on, press the Elevation/ Slope button, until the yellow LED below to the slope
symbol illuminates (Figure 127).
Figure 127: Setting the Control Box to Slope Mode
4. To display the actual slope percentage, press Survey.
If the On-Grade bar is illuminated, and the screen displays a slope value that is identical to the laser
or Smart Level, press the Auto button to put the Control Box into Automatic control, and begin
paving.
If the slope displayed in the box does not match the surface, then you must calibrate the Slope
Sensor.
--
--
--
--
--
--
--
--
--
--
--
--
--
POWER
POWER
--
--
--
--
--
--
--
--
--
--
--
--
--
+
2.0% SLOPE
Elevation/Slope
You must turn Off Slope Calibration Block in the Performance Menu before calibrating the Slope
Sensor.