23 SPECIFICATIONS
Measurement accuracy / Least Count in Measurement/Measurement Time
zPrism mode D:Measuring distance(mm)
zNon-prism mode (Diffusing Surface) D:Measuring distance
*1)The initial time will be different by a condition.
*2)However, when the measurement distance is more than 100 m, or when the reflectance of the
measured surface is low, measurement time will become longer.
Laser class for distance measurement : Class 1M(IEC Publication 825)
: Class I(FDA/BHR 21 CFR 1040)
Measurement Display : 12 digits : max. display 99999999.9999
Atmospheric Correction Range : –999.9 ppm to +999.9 ppm, in 0.1 ppm increments
Prism Constant Correction Range : –99.9 mm to +99.9 mm, in 0.1 mm increments
Coefficient Factor : Meter / Feet
International feet 1meter = 3.28083989501 ft.
US SURVEY feet 1meter = 3.28083333333 ft.
Measurement mode Measurement accuracy Least Count
in Measurement
Measurement
Time *1
Fine
0.2mm mode
± (2mm +2ppm × D)
m.s.e.
0.2mm
(0.001ft)
1.5 sec.
(Initial 3 sec.)
1mm mode 1mm
(0.005ft)
1.1 sec.
(Initial 2.5 sec.)
Coarse
1mm mode
± (7mm +2ppm × D)
m.s.e.
1mm
(0.005ft) 0.8 sec.
(Initial 2.5 sec.)
10mm mode 10mm
(0.02ft)
Tracking ± (10mm +2ppm × D)
m.s.e.
10mm
(0.02ft)
0.5 sec.
(Initial 2.5 sec.)
Measurement mode Measurement accuracy Least Count
in Measurement
Measurement
Time *1*2)
Fine
0.2mm mode
± (3mm+2ppm*D) m.s.e.
0.2mm
(0.001ft)
2.6 sec.
(Initial 3.5 sec.)
1mm mode 1mm
(0.005ft)
1.7 sec.
(Initial 3 sec.)
Coarse
1mm mode
± (10mm) m.s.e.
1mm
(0.005ft) 1 sec.
(Initial 2 sec.)
10mm mode 10mm
(0.02ft)
Tracking ± (10mm) m.s.e. 10mm
(0.02ft)
0.4 sec.
(Initial 2 sec.)