3-4
3 ANGLE MEASUREMENT
3.5 Repetition Angle Measurement
zRepetition angle measurement can be done by horizontal angle right measurement mode.
Make sure the mode is Horizontal Angle Right measurement.
Operating procedure Operation Display
1Press the [F4](
) key to get the function on page 2. [F4]
2Press the [F2](REP)key. [F2]
3Press the [F3](YES) key. [F3]
4Collimate the target A and press the [F1] (0SET)
key. Collimate A
[F1]
5Press the [F3] (YES) key. [F3]
6Collimate the target B using the horizontal clamp
and tangent screw.
Press the [F4](HOLD) key.
Collimate B
[F4]
7Recollimate target A using the horizontal clamp
and tangent screw, and press the [F3](REL)key. Collimate A
[F3]
8Recollimate target B using the horizontal clamp
and tangent screw, and press the [F4](HOLD) key. Collimate B
[F4]
9Repeat 7 to 8 to measure the desired number of
repetitions.
[Example] 4 measurement
V : 90°10'20"
HR: 170°30'20"
0SET HOLD HSET P1
TILT REP V% P2
REPETITION ANGLE
> OK?
--- --- [YES][NO]
REP-ANGLE COUNT[ 0]
Ht: 0°00'00"
Hm:
0SET V/H REL HOLD
REPETITION ANGLE
INITIALIZE
> OK?
--- --- [YES][NO]
REP-ANGLE COUNT[ 0]
Ht: 0°00'00"
Hm:
0SET V/H REL HOLD
REP-ANGLE COUNT[ 1]
Ht: 45°10'00"
Hm: 45°10'00"
0SET V/H REL HOLD
REP-ANGLE COUNT[ 1]
Ht: 45°10'00"
Hm: 45°10'00"
0SET V/H REL HOLD
REP-ANGLE COUNT[ 2]
Ht: 90°20'00"
Hm: 45°10'00"
0SET V/H REL HOLD
REP-ANGLE COUNT[ 4]
Ht: 180°40'00"
Hm: 45°10'00"
0SET V/H REL HOLD
Loading...