Loading...
4-9
4 DISTANCE MEASUREMENT
4.7.2 Distance Offset Measurement
The measurement of a place apart from a prism is possible by inputting offset horizontal distance of
front and back / right and left.
When measuring coordinates of ground point A1: Set the instrument height / prism height.
When measuring coordinates of point A0: Set the instrument height only.
(Set the prism height to 0 ).
Operating procedure Operation Display
1Press the [F4](P1
) key from distance measuring
mode to get the function on page 2. [F4]
2Press the [F1](OFSET) key. [F1]
3Press the [F2](DIST. OFFSET) key. [F2]
4Enter Right and Left direction offset value, and
press the [F4](ENTER) key. Enter HD
[F4]
5Enter Forward direction offset value, and press
the [F4](ENTER) key. Enter HD
[F4]
6Collimate prism P, and press the [F1](MEAS) key.
Measuring will start. Collimate
P1
[F1]
A
1
A
0
oHD sign
Forward HD
RorL HD
Prism height
Prism P
Occ.Point
Instrument height
HR: 120°30'40"
HD: 123.456 m
VD: 5.678 m
MEAS MODE NP/P P1
OFSET S.O S/A P2
OFFSET 1/2
F1:ANG.OFFSET
F2:DIST.OFFSET
F3:PLANE OFFSET P
DISTANCE OFFSET
INPUT RorL HD
oHD= m
--- --- [CLR] [ENT]
DISTANCE OFFSET
INPUT FORWARD HD
oHD= m
--- --- [CLR] [ENT]
DISTANCE OFFSET
HR: 80°30'40"
HD: m
MEAS --- NP/P ---
DISTANCE OFFSET
HR: 80°30'40"
HD* [n] << m
>Measuring...
Loading...
Terms of Use | Privacy Policy | DMCA Policy
2006-2020 Rsmanuals.com