Loading...
6-17
6 SPECIAL MODE (Menu Mode)
6.3 Setting Illumination of Display and Cross Hairs
Setting ON/OFF/LEVEL (1 to 9) for illumination of display (LCD) and reticle.
Setting LEVEL (1 to 9) is only for reticle.
[Example setting] LEVEL:2 and turn on the illumination.
3Press the [F3](YES) key.
4Enter Elevation. *1) Press the [F4](ENT) key.
[F3]
Enter ELEV.
[F4]
5Enter Scale Factor in the same way. Enter Scale
[F4]
Grid Factor is displayed for 1 to 2 second and
display returns to menu.
*1) Refer to Section 2.6 “How to Enter Alphanumeric characters”.
zInput Range :Elevation : –9,999 to +9,999 meter (–32,805 to +3,2805 ft, ft+in)
Scale Factor: 0.990000 to 1.010000
Operating procedure Operation Display
1After pressing the [MENU] key, press the [F4](P
)
key to get the menu on page 2. [MENU]
[F4]
2Press the [F3] key.
The data previously set is shown. [F3]
3Press the [F3](LEVEL) key.
4Press the [F2]() key, and then press the
[F4](ENTER) key.
[F3]
[F2]
[F4]
5Press the [F1](ON) key. [F1]
zTo return to previous mode, press the [ESC] key.
GRID FACTOR
ELEV.=1000 m
SCALE:0.999000
--- --- [CLR] [ENT]
GRID FACTOR
ELEV.:2000 m
SCALE=1.001000
--- --- [CLR] [ENT]
GRID FACTOR
=1.000686
MENU 2/3
F1:PROGRAMS
F2:GRID FACTOR
F3:ILLUMINATION P
ILLUMINATION [OFF:1]
F1:ON
F2:OFF
F3:LEVEL
ILLUMINATION [OFF:1]
[LEVEL MODE]
––– ENTER
ILLUMINATION [OFF:2]
F1:ON
F2:OFF
F3:LEVEL
ILLUMINATION [ON:2]
F1:ON
F2:OFF
F3:LEVEL
Loading...
Terms of Use | Privacy Policy | DMCA Policy