7. APPLIED OPERATION AND SETTING OF VARIOUS FUNCTIONS
40
The laser beam can be moved to the direction of the key during vertical rotation.
Only the X axis can be moved.
Allowable alignment range: ±5° (when the instrument is set up on the 0° surface)
1Set the instrument.
2Press the Power control key to turn unit on. When
auto leveling is complete, the laser beam will be
rotate vertically.
3Move and set the RL-SV1S to align reference point
A and the laser beam.
Make sure that the RL-SV1S is set so that the
bubble is at the center of the vertical rotation
circular level vial on the control panel.
7.2 Line Control (manual vertical beam alignment)
LS-80L
key
key
If it is unable to visually confirm the laser
beam on reference point A and B, set up the
LS-80L on either of the Points.