Keypa
d Notes
ARMED
READY
1OFF
4MAX
7
INSTANT
READY
2AWAY
5TEST
8CODE
0
3STAY
6
BYPASS
9CHIME
#
'$4'
6 (*$
!""'G/D.*G/D@% '
!""&&
&$
7%&((.
$)"(/.Q/$
;<=>;?7
••
88+'$$@#"# &&@#E.1C
&&&
$
••
8+'/#A@
G/ED$
••
18+'8+''')
@#".'/$.$DKE/?#E/-# &&'
/$/$/"A$
Optional
VISTA
-
GSM4G
Module
49#:,:  
C$
1M&.?$
Wire Run Chart For Devices* Drawing Aux Power From The Control (12V+ & 12V
Wire
TOTAL CURRENT DRAWN BY ALL DEVICES CONNECTED TO A SINGLE WIRE RUN
Si
ze
50 mA or less
100 mA
300 mA
500 mA
600 mA
#22
900 ft (274m)
450 ft (137m)
150 ft (46m)
90 ft (27m)
75 ft (23m)
#20
1400 ft (427m)
700 ft (213m)
240 ft (73m)
140 ft (43m)
120 ft (37m)
#18
1500 ft (457m)
1100 ft (335m)
350 ft (107m)
220 ft (67m)
170 f
t (52m)
#16
1500 ft (457m)
1500 ft (457m)
550 ft (168m)
350 ft (107m)
270 ft (82m)
*
Includes Keypads, RF Receivers, Zone Expander/Relay Units, and 4286 Phone Module.
Maximum wire lengths for any device that is homerun to the control can also be determined from the Wiring Run Chart, based on the current draw of that device
alone.
The length of all wire runs for both partitions combined must not exceed 1500 feet (457m) when unshielded quad conductor cable is used (750 feet if shielded
cable is used). This restriction is due to the capacitive effect on the data lines when quad cable is used.
Table of Device Addresses
This Device
Uses Address
Reports as
††
Enabled By…
RF Receiver
00
100
*56 zone programming: input dev
ice type entry
AUI 1
01
automatic if AUI enable field *189 enabled for AUI 1
AUI 2
02
automatic if AUI enable field *189 enabled for AUI 2
AUI 3
05
automatic if AUI enable field *189 enabled for AUI 1
AUI 4
06
automatic if AUI enable field *189 ena
bled for AUI 2
Internal IP/GSM
Device
03
103
automatic if
enabled in
menu mode
*29
4286 Voice Module
04
104
automatic if phone module access code field *28 enabled
Zone Expanders (4219/4229):
module 1 (for zones 09 - 16)
module 2 (for zones 17 - 24)
module 3 (for zones 25 - 32)
module 4 (for zones 33 - 40)
module 5 (for zones 41 - 48)
07**
08
09
10
11
107
108
109
110
111
*56 zone programming: input device type, entry 2, then:
automatic if zone no. 9-16 set as AW type or relay assigned
automatic if zone no. 17-24 set as AW type or relay assigned
automatic if zone no. 25-32 set as AW type or relay assigned
automatic if zone no. 33-40 set as AW type or relay assigned
automatic if zone no. 41-48 set as AW type or relay assigned
Relay Modules (4204):
module 1
module 2
module 3
module 4
12
13
14
15
112
113
114
115
*79 output device programming: device address prompt:
entered at device address prompt
entered at device address prompt
entered at device address prompt
entered at device address prompt
Keypads:
keypad 1
keypad 2
keypad 3
keypad 4
keypad 5
keypad 6
keypad 7
keypad 8
16
17
18
19
20
21
22
23
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
data field programming as listed below:
always enabled for partition 1, all sounds enabled.
data field *190
data field *191
data field *192
data field *193
data field *194
data field *195
data field *196
RIS
Communication
25
n/a
automatic
(
used
for Remote Interactive Services)
5800TM Module
28
n/a
automatic
** address 07 not available if zone-doubling enabled
†† Addressable devices are identified by “1” plus the device address when reporting. Enter a report code for zone 91 to enable addressable device reporting
(default = reports enabled). See field *199 for addressable device (ECP) 3-digit/2-digit identification keypad display options.