CLASS 2 PLUG-IN TRANSFORMER
16.5VAC, 40VA
(e.g. ADEMCO No. 1361)
(USE No. 1361CN IN CANADA)
+
THIS EQUIPMENT SHOULD BE INSTALLED IN
ACCORDANCE WITH THE NATIONAL FI R E
PROTECTION ASS O C I ATION'S
STANDARD 72 (NATIONAL FIRE
PROTECTION ASSOCIATION,
BATTERYM A R C H PARK, Q U I N CY,
MA 0216 9 ) .
PRINTED I N F O R MATION D E S C R I BING
PROPER INSTALLATION, OPERATIO N,
TESTING, MAINTENANCE, EVACUATION
PLANNING AND REPAIR SERVICE IS TO BE
PROVIDED WITH THIS EQUIPMENT.
24-HR BATTERY STANDBY REQUIRED FOR
FIRE INSTALLATIONS. USE 12V, 17.2AH
BATTERY FOR 600mA AUX POWER. SEE
INSTRUCTIONS.
BATTERY CAPACITY FOR EMERGENCY
BURGLARY STANDBY USE AT LEAST 4 HRS
USE UL LISTED LIMITED ENERGY
CABLE FOR ALL CONNECTIONS
FOR COMPLETE
INFORMATION,
SEE INSTRUCTIONS
K14488V3 OR LATER.
ALARM OUTPUT
10.5–13.8VDC, 2A MAX. (600mA
MAX. FOR UL USAGE,
INCLUDING AUX POWER)
STEADY FOR BURGLARY/PANIC,
TEMPORAL PULSE SOUNDING
FOR FIRE. CAN USE ADEMCO
No. 702 SIREN, OR 12V BELL).
SEE INSTRUCTIONS.
FOR BELL SUPERVISION, ENABLE
FIELD 91 AND CONNECT
820 OHM RESISTOR DIRECTLY
ACROSS EXTERNAL SOUNDER.
TO INTERNET
CONNECTION
CHARGING VOLTAGE 13.8VDC. MAXIMUM
CHARGING CURRENT 650mA.
SEALED LEAD-ACID TYPE.
BATTERY NORMALLY NEED NOT BE
REPLACED FOR AT LEAST 3 YRS.
TO DETERMINE TOTAL STANDBY LOAD
ON BATTERY, ADD 100mA TO TOTAL OF
AUX. POWER OUTPUT AND REMOTE
KEYPAD CURRENTS.
BATTERY
12V, 4AH
IP/GSM SWITCHES
TEST STATUS
LED
INDICATOR
CONNECTION OF THE FIRE ALARM SIGNAL
TO A FIRE ALARM HEADQUARTERS OR A
CENTRAL STATION SHALL BE PERMITTED
ONLY WITH THE PERMISSION OF THE LOCAL
AUTHORITY HAVING JURISDICTION.
THE BURGLAR ALARM SIGNAL SHALL NOT
BE CONNECTED TO A POLICE EMERGENCY
NUMBER.
GND Z5Z4GNDZ3Z2GNDZ1+YELGRNAUXAC AC BELL GND GNDRINGTIPRINGTIPZ8GND Z6 Z7
1312 25
EARTH
GROUND
SEE
INSTRUCTIONS
FOR PROPER
GROUNDING
TELEPHONE WIRING
(VIA RJ31X* JACK AND DIRECT
CONNECT CORD)
BLACK: KEYPAD GROUND (- ) RETURN
RED: KEYPAD PWR ( + )
GREEN: DATA IN FROM KEYPAD
YELLOW: KEYPAD DATA OUT
KEYPADS AND OTHER
ADDRESSABLE
DEVICES AND/OR
EXPANDER MODULES
(UP TO 40
ADDITIONAL ZONES)
4219, 4229, 4204: SET
DIP SW ADDR. 7-15
5881: SET DIP SW TO
ADDR. "0".
SEE MODULE'S
INSTRUCTIONS
(GRAY) (GREEN) (RED)
INCOMING
PHONE LINE
HANDSET
ZONE 1
HI
LO
HI
LO
ZONE 3
ZONE 4
HI
LO
HI
LO
ZONE 5
ZONE 6
HI
LO
HI
LO
ZONE 7
ZONE 8
HI
LO
HI
LO
MAX LOOP RESISTANCE: (EACH ZONE) 300 OHMS
(PLUS EOLR)
RESPONSE, ZONES 1-8: 10, 350, OR 700 MSEC
(PROGRAMMABLE)
8-PIN CONNECTOR
FOR 1361X10 TRANS.
AND ON-BOARD TRIGGERS
SEE INSTRUCTIONS.
7 8
(BROWN)
}
}
ZONE 1 CAN BE USED FOR 2-WIRE SMOKE DETECTORS
NOTE:
KEYPAD (S)
CURRENT (IN BOTH
PARTITIONS) AND
ALL OTHER DEVICES
DRAWING POWER
FROM TERMS 4 & 5
MUST BE INCLUDED
IN AUX CURRENT
DRAIN CALCULATIONS.
AUX. POWER
OUTPUT
10.5-13.8VDC
600mA MAX.
(500mA MAX.
FOR UL
INSTALLATIONS)
ALL OUTPUTS
ARE POWER
LIMITED.
+
2000
OHMS
EOLR
2000
OHMS
EOLR
2000
OHMS
EOLR
2000
OHMS
EOLR
2000
OHMS
EOLR
2000
OHMS
EOLR
2000
OHMS
EOLR
2000
OHMS
EOLR
SYNC
COM
DATA
GND
+12 AUX
10
9
6
1 2 3 4 5 6
OUTPUT 18
(TRIG. 2)
OUTPUT 17
(TRIG. 1)
MAXIMUM NUMBER OF 2-WIRE SMOKE DETECTORS
ON ZONE 1 IS 16; DETECTORS MUST HAVE
COMPATIBILITY IDENTIFIER AS "A".
ZONE
PAIRS
2 / 10
3 / 11
4 / 12
5 / 13
6 / 14
7 / 15
8 / 16
ADEMCO VISTA-21iP / VISTA-21iPSIA
SUMMARY OF CONNECTIONS
1312 14
10 11
6.2k
ZONE 10
3k
ZONE 2
2k
2k
2k
ZONE 3
2k
2k
2k
ZONE 4
TAMPER
CONTACTS
TAMPER
CONTACTS
TYPICAL WIRING FOR
ZONE DOUBLING
TYPICAL WIRING FOR
DOUBLE BALANCED ZONE
REMOTE KEYPADS
CAN USE 6150 OR 6160
KEYPADS. LOCAL
PROGRAMMING
MUST BE DONE WITH A
6139/6160, BUT NEED NOT
REMAIN IN THE SYSTEM
(SET TO ADDRESS 16).
BLK
DOC LOAD NO.: 3
WARNING:
TO P R E V ENT RISK OF SHOCK, D I S C O N N ECT
TELEPHONE LINE AT T E L C O JACK BEFORE S E RVICING
THIS UNIT.
FOR CONNECTION OF OPTIONAL 4286 VIP MODULES
TO PHONE TERMINALS, SEE INSTRUCTIONS.
COMPLIES WITH FCC RULES, PART 68. FCC REGISTRATION
NO. 5GBUSA-44003-AL-E RINGER EQUIVALENCE: 0.1B.
ALL DEVICES AND
ACCESSORIES USED IN A
CANADIAN INSTALLATION
MUST BE LISTED FOR
USE IN CANADA
POWER SHUTDOWN NOTE:
SYSTEM SHUTS DOWN
SENSOR DETECTION
PROCESSING IF
CONTROL'S VOLTAGE
DROPS BELOW 9.6V.
4-WIRE SMOKE DETECTOR CONNECTIONS
+
+
V21iP-SOC-V1
2000
OHMS
EOLR
HEAT
DETECTOR
RED
EOL
POWER
SUPERVISION
RELAY MODULE
EOLR-1.
USE N.O.
CONTACT,
WHICH CLOSES
WHEN POWER
IS APPLIED.
VIOLET
AUX PWR
OUTPUT
TERMINALS
5
4
_
_
+
BLK _
TO ZONE TERM. ( )
TO ZONE TERM. ( )
RELAY
CONTACT OPENS MOMENTARILY
UPON FIRE ALARM RESET
PROGRAM RELAY
AS ZONE TYPE 54
(FIRE ZONE RESET)
_
+
4-WIRE SMOKE
OR COMBUSTION
DETECTOR
N.C. N.O.
TO OUTPUT 17
PROGRAM OUTPUT 17 FOR
"OUT NORM LOW" = YES IN
79 MENU MODE AND AS ZONE
TYPE 54 IN 80 MENU MODE
MAX. CURRENT = 100 mA
OR
WEEKLY TESTING IS REQUIRED TO ENSURE PROPER
OPERATION OF THIS SYSTEM. IN ADDITION, THIS
SYSTEM MUST BE CHECKED BY A QUALIFIED
TECHNICIAN AT LEAST ONCE EVERY THREE (3) YEARS.
*CA38A IN CANADA
BATTERY FUSE
FOR REPLACEMENT,
USE SAME VALUE
(e.g. ADEMCO No. 90-12)
4A
BLACK
RED
(FLYING LEADS FOR
BATTERY CONNECTION)
TO
1361X10
TRANS
GSM MODULE (OPTIONAL)
Z1-
CAUTION: ESD SENSITIVE DEVICE
To guard against static discharge damage while installing this module, briefly touch
a chassis ground point in the Control Panel cabinet to discharge any static buildup.
Avoid performing this installation while standing on a carpeted floor because a
carpeted floor increases the possibility of static buildup.
RJ4 5
CON N E CTO R
ETHERNET LINK/ACTIVITY (ON=YES; OFF=NO)
LINK SPEED (ON=100 MB/S; OFF=10 MB/S)
NETWORK COLLISION (BLINK=DETECTED; OFF= NORMAL)
GRN
GRN
YEL
STATUS (ON=NOT REGISTERED; OFF = REGISTERED)
MESSAGE
FAULT (ON=NO NETWORK CONTACT; BLINK = PANEL FAULT)
GRN
YEL
RED
IP (WEB)
NETWORK
LEDs
IP/GSM STATUS LEDs
RSSI
MODE 1
MODE 2
WEB
GPRS
GSM
SIGNAL STRENGTH
AND STATUS LEDs
RED
YEL
YEL
GRN
GRN
GRN
RSSI
MINIMUM
LIT
ON = RSSI
OFF = STATUS; ON = RSSI
OFF = NO WEB CONNECTION; ON = CONNECTED TO WEB
OFF = NO GPRS SERVICE; FLASH = GPRS IN USE; ON = GPRS AVAILABLE
OFF = NOT REGISTERED w/CARRIER; BLINK/ON = REGISTERED w/NETWORK CARRIER
OFF = ECP MODE
STATUS LED INDICATIONS
TO 110VAC
UNSWITCHED OUTLET (24HR)
USE 1361X10 TRANSFORMER INTERFACE
IN PLACE OF 1361 OR 1361CN WHEN POWER
LINE CARRIER DEVICES ARE BEING USED.
(SEE INSTRUCTIONS FOR CONNECTIONS)
24
23
22
21
20
11
8
7
5
24
INTERNAL
IP/GSM
JUMPER
ON
OFF
16 19
18
17
15
13 14
Figure 17. Summary of Connections