Loading...
A - 11
Appendices
EtherCAT Communication Unit USER’S MANUAL (I574-E1)
A-4 MX2 Series Parameter List
A
3000
hex
27
hex
0026 hex Fault Monitor 3
Cause
d083 RO Refer to MX2 Inverter fault factor list
on page P. A-12.
Possible
(TxPDO)
3000
hex
28
hex
0027 hex Fault Monitor 3
Inverter Status
Refer to MX2 Inverter fault factor list
on page P. A-12.
Possible
(TxPDO)
4000
hex
29
hex
0028 hex Fault Monitor 3
Frequency
0 to 100000 0.01 [Hz] Possible
(TxPDO)
3000
hex
2B
hex
002A
hex
Fault Monitor 3
Current
Output current value at the time of
tripping
0.01 [A] Possible
(TxPDO)
3000
hex
2C
hex
002B
hex
Fault Monitor 3
Voltage
DC input voltage at the time of
tripping
0.1 [V] Possible
(TxPDO)
4000
hex
2D
hex
002C
hex
Fault Monitor 3
RUN Time
Total RUN time at the time of
tripping
1 [h] Possible
(TxPDO)
4000
hex
2F
hex
002E
hex
Fault Monitor 3
ON Time
Power ON time at the time of
tripping
1 [h] Possible
(TxPDO)
3000
hex
31
hex
0030 hex Fault Monitor 4
Cause
d084 RO Refer to MX2 Inverter fault factor list
on page P. A-12.
Possible
(TxPDO)
3000
hex
32
hex
0031 hex Fault Monitor 4
Inverter Status
Refer to MX2 Inverter fault factor list
on page P. A-12.
Possible
(TxPDO)
4000
hex
33
hex
0032 hex Fault Monitor 4
Frequency
0 to 100000 0.01 [Hz] Possible
(TxPDO)
3000
hex
35
hex
0034 hex Fault Monitor 4
Current
Output current value at the time of
tripping
0.01 [A] Possible
(TxPDO)
3000
hex
36
hex
0035 hex Fault Monitor 4
Voltage
DC input voltage at the time of
tripping
0.1 [V] Possible
(TxPDO)
4000
hex
37
hex
0036 hex Fault Monitor 4
RUN Time
Total RUN time at the time of
tripping
1 [h] Possible
(TxPDO)
4000
hex
39
hex
0038 hex Fault Monitor 4
ON Time
Power ON time at the time of
tripping
1 [h] Possible
(TxPDO)
3000
hex
3B
hex
003A
hex
Fault Monitor 5
Cause
d085 RO Refer to MX2 Inverter fault factor list
on page P. A-12.
Possible
(TxPDO)
3000
hex
3C
hex
003B
hex
Fault Monitor 5
Inverter Status
Refer to MX2 Inverter fault factor list
on page P. A-12.
Possible
(TxPDO)
4000
hex
3D
hex
003C
hex
Fault Monitor 5
Frequency
0 to 100000 0.01 [Hz] Possible
(TxPDO)
3000
hex
3F
hex
003E
hex
Fault Monitor 5
Current
Output current value at the time of
tripping
0.01 [A] Possible
(TxPDO)
3000
hex
40
hex
003F
hex
Fault Monitor 5
Voltage
DC input voltage at the time of
tripping
0.1 [V] Possible
(TxPDO)
4000
hex
41
hex
0040 hex Fault Monitor 5
RUN Time
Total RUN time at the time of
tripping
1 [h] Possible
(TxPDO)
4000
hex
43
hex
0042 hex Fault Monitor 5
ON Time
Power ON time at the time of
tripping
1 [h] Possible
(TxPDO)
3000
hex
45
hex
0044 hex Fault Monitor 6
Cause
d086 RO Refer to MX2 Inverter fault factor list
on page P. A-12.
Possible
(TxPDO)
3000
hex
46
hex
0045 hex Fault Monitor 6
Inverter Status
Refer to MX2 Inverter fault factor list
on page P. A-12.
Possible
(TxPDO)
4000
hex
47
hex
0046 hex Fault Monitor 6
Frequency
0 to 100000 0.01 [Hz] Possible
(TxPDO)
3000
hex
49
hex
0048 hex Fault Monitor 6
Current
Output current value at the time of
tripping
0.01 [A] Possible
(TxPDO)
3000
hex
4A
hex
0049 hex Fault Monitor 6
Voltage
DC input voltage at the time of
tripping
0.1 [V] Possible
(TxPDO)
4000
hex
4B
hex
004A
hex
Fault Monitor 6
RUN Time
Total RUN time at the time of
tripping
1 [h] Possible
(TxPDO)
4000
hex
4D
hex
004C
hex
Fault Monitor 6
ON Time
Power ON time at the time of
tripping
1 [h] Possible
(TxPDO)
3000
hex
4F
hex
004E
hex
Warning Monitor d090 RO Warning code Possible
(TxPDO)
3009
hex
13
hex
0900 hex EEPROM Write WO 0: Motor parameter recalculation
1: Set value storage in EEPROM
Other: Motor parameter recalculation
and EEPROM
Not
possible
3009
hex
15
hex
0902 hex EEPROM Write Mode
Selection
WO 0: Write disabled
1: Write enabled
Not
possible
Index Sub-
index
Register
No. Function name Parameter
No. R/W Monitor and setting items
Data
resolution
PDO
map
Loading...
Terms of Use | Privacy Policy | DMCA Policy