Loading...
Appendices
A - 36 EtherCAT Communication Unit USER’S MANUAL (I574-E1)
3000
hex
3B
hex
003A
hex
Fault Monitor 5 Cause d085 RO Refer to RX-V1 Inverter fault factor
list on page P. A-37.
Possible
(TxPDO)
3000
hex
3C
hex
003B
hex
Fault Monitor 5
Inverter Status
Refer to RX-V1 Inverter fault factor
list on page P. A-37.
Possible
(TxPDO)
4000
hex
3D
hex
003C
hex
Fault Monitor 5
Frequency
0 to 40000 0.01 [Hz] Possible
(TxPDO)
3000
hex
3F
hex
003E
hex
Fault Monitor 5
Current
Output current value at the time of
tripping
0.1 [A] Possible
(TxPDO)
3000
hex
40
hex
003F
hex
Fault Monitor 5
Voltage
DC input voltage at the time of
tripping
0.1 [V] Possible
(TxPDO)
4000
hex
41
hex
0040 hex Fault Monitor 5 RUN
Time
Total RUN time at the time of
tripping
1 [h] Possible
(TxPDO)
4000
hex
43
hex
0042 hex Fault Monitor 5 ON
Time
Power ON time at the time of
tripping
1 [h] Possible
(TxPDO)
3000
hex
66
hex
0065 hex Fault Monitor 5
Detection Year
Year at the time of tripping (enabled
when the LCD digital operator is
connected)
BCD Possible
(TxPDO)
3000
hex
67
hex
0066 hex Fault Monitor 5
Detection Date
Date at the time of tripping (enabled
when the LCD digital operator is
connected)
BCD Possible
(TxPDO)
3000
hex
68
hex
0067 hex Fault Monitor 5
Detection Time
Time at the time of tripping (enabled
when the LCD digital operator is
connected)
BCD Possible
(TxPDO)
3000
hex
45
hex
0044 hex Fault Monitor 6 Cause d086 RO Refer to RX-V1 Inverter fault factor
list on page P. A-37.
Possible
(TxPDO)
3000
hex
46
hex
0045 hex Fault Monitor 6
Inverter Status
Refer to RX-V1 Inverter fault factor
list on page P. A-37.
Possible
(TxPDO)
4000
hex
47
hex
0046 hex Fault Monitor 6
Frequency
0 to 40000 0.01 [Hz] Possible
(TxPDO)
3000
hex
49
hex
0048 hex Fault Monitor 6
Current
Output current value at the time of
tripping
0.1 [A] Possible
(TxPDO)
3000
hex
4A
hex
0049 hex Fault Monitor 6
Voltage
DC input voltage at the time of
tripping
0.1 [V] Possible
(TxPDO)
4000
hex
4B
hex
004A
hex
Fault Monitor 6 RUN
Time
Total RUN time at the time of
tripping
1 [h] Possible
(TxPDO)
4000
hex
4D
hex
004C
hex
Fault Monitor 6 ON
Time
Power ON time at the time of
tripping
1 [h] Possible
(TxPDO)
3000
hex
6B
hex
006A
hex
Fault Monitor 6
Detection Year
Year at the time of tripping (enabled
when the LCD digital operator is
connected)
BCD Possible
(TxPDO)
3000
hex
6C
hex
006B
hex
Fault Monitor 6
Detection Date
Date at the time of tripping (enabled
when the LCD digital operator is
connected)
BCD Possible
(TxPDO)
3000
hex
6D
hex
006C
hex
Fault Monitor 6
Detection Time
Time at the time of tripping (enabled
when the LCD digital operator is
connected)
BCD Possible
(TxPDO)
3000
hex
4F
hex
004E
hex
Warning Monitor d090 RO Warning code Possible
(TxPDO)
3009
hex
13
hex
0900 hex EEPROM Write WO 0: Motor parameter recalculation
1: Set value storage in EEPROM
Other: Motor parameter recalculation
and EEPROM
Not
possible
3009
hex
15
hex
0902 hex EEPROM Write Mode
Selection
WO 0: Write disabled
1: Write enabled
Not
possible
Index Sub-
index
Register
No. Function name Parameter
No. R/W Monitor and setting items
Data
resolution
PDO
map