Heatseeker Zero Clearance Timber Frame Installation
Floor 0 mm
Sides 25 mm
Top 100 mm
Flue Outer 25 mm
CLEARANCES FROM
COMBUSTIBLES
NOTE: If fire is to be installed off the floor with a 4 sided
trim, use the same A, B, C and D dimensions as shown with
framework included below fire to required height. Ensure
frame is suitable for fire weight.
HEATSEEKER ZERO CLEARANCE MODEL
MODEL AB C D
600 750 750 450 2100
850 750 1000 450 2100
1000 750 1150 450 2100
Frameout Dimensions (in mm)
IMPORTANT
Install unit and
fluing before
plasterboard.
A
A
B
B
CC
D
(Recommended only)
From hearth
Approx 20mm for
hearth if required.
D
(Recommended only)
HEATER
TRIM
Plaster to run
beyond stud and
behind trim
Plasterboard to run beyond stud as shown,
and to go behind fixing flange on unit.
Min 25mm
clearance