Installation, Operation and Maintenance Manual
Control Valves Electric Actuated Type M 14
Recommended torque value Unit Nmkgfcm󲽚[lbinch]
Nom. Size 15 mm
(1/2”)
25 mm
(1”)
50 mm
(2”)
80, 100 mm
(3”, 4”)
PTFEPVDF
coated
17.5
{179}
[155]
20.0
{204}
[177]
22.5
{230}
[230]
30.0
{306}
[266]
Rubber
8.0
{82}
[71]
20.0
{204}
[177]
22.5
{230}
[230]
30.0
{306}
[266]
(10) Support setting procedure
- Do not subject the valve to pump vibrations. (The valve may be damaged.)
- When installing a pipe support by means of a U-band or something similar, take care not to fasten it
too much. (Excessive tension may damage it.)
- Valves must be supported. (The valve may be damaged by the weight of the actuator if it is unsupported.)
Spanner wrench U-type clamp (with bolt) Rubber sheet
Level installation
Set the stand under the valve.
Only for nominal size 15, 25mm (1/2”, 1”), the Ensat
which is equipped to the body enables the valve to fix
to the stand. Refer to the chart below.
Dimension of Ensat
Nominal Size 15, 25mm (1/2”, 1”)
Ensat M6
Spread the rubber sheet on the pipe and secure with
U-type clamp.
Perpendicular installation
Set the stand under the actuator and the actuator stand.
Only for nominal size 15, 25mm (1/2”, 1”), the Ensat
which is equipped to the body enables the valve to fix
to the stand. Refer to the chart above.
Spread the rubber sheet on the pipe and secure with
U-type clamp.
Fig. 1
Necessary items
Caution
Stand
Rubber sheet
U-type clamp
Level installation
Ensat
Stand
U-type clamp
Perpendicular installation
Rubber sheet