Installation, Operation and Maintenance Manual
󲷇H-A058-E-12󲷈 Diaphragm Valve, True Union Diaphragm Valve (15-50mm, 1/2”-2”) Pneumatic Actuated Type AI
12
(9) Support setting procedure
- Do not subject the valve pump vibrations. (The valve may be damaged.)
- Set the valve support. (The valve may be damaged because the actuator is heavy.)
Spanner wrench U-type clamp (with bolt) Rubber sheet
Level plumber
Using metal insert (Ensert) & U-type clamp
Fix the installation jig (under the valve) and stand with
bolts (Bolt size: M5)
Spread the rubber sheet on the pipe and secure pipe
with U-type clamp.
Using U-type clamp (Only Flanged type)
Spread the rubber sheet on the pipe and secure pipe
with U-type clamp.
Perpendicular plumber
Fix the installation jig (under the valve) and stand with bolts
(Refer to page 21)
Spread the rubber sheet on the pipe and secure pipe with U-
type clamp.
Caution
Necessary items