Installation, Operation and Maintenance Manual
󲷇H-A058-E-12󲷈 Diaphragm Valve, True Union Diaphragm Valve (15-50mm, 1/2”-2”) Pneumatic Actuated Type AI
21
(14) Mounting insert-metal and base (panel)
- When screwing in a Metal Insert (Ensat), install it vertically. Refer to the User's Manual for Metal Insert
(Ensat) by the Maker.
Procedure
Refer to the user’s manual for the Ensat (Insert metal)
Commercially available.
Bottom stand dimension
Unit ; mm (inch)
Nom. Size
S1
S2
S3
15mm-32mm
(1/2”, 1 1/4”)
25
(0.98)
7
(0.28)
13
(0.51)
40mm, 50mm
(1 1/2”, 2”)
45
(1.8)
9
(0.35)
15
(0.59)
Panel mount procedure
Before
After