Installation, Operation and Maintenance Manual
Butterfly Valves Type 75, 75D Pneumatic Actuated Type TW 11
(12) Support setting procedure
- Set the valve support. (If not, the valve may be damaged because the actuator is heavy.)
- Do not subject the valve to pump vibration. (The valve may be damaged.)
Spanner wrench U-type clamp (with bolt) Rubber sheet
Level installation
Set the stand under the valve.
Spread the rubber sheet on the pipe and secure pipe with
U-type clamp.
Perpendicular installation
Spread the rubber sheet under the actuator.
Spread the rubber sheet on the pipe and secure pipe with
U-type clamp.
Necessary items
Caution