Installation, Operation and Maintenance Manual
󲷇H-A069-E󲷈 Ball Valve Type2121α Pneumatic Actuated Type AR 15-50mm (1/2”-2”) 24
18Mounting insert-metal and base (panel)
󲼙
Attach Inserted metal to the bottom stand
- When screwing in a Metal Insert (Ensat), install it vertically.
- Refer to the User's Manual for Metal Insert (Ensat) by the maker.
Procedure
Refer to the user’s manual for the Metal Insert (Ensat).
Bottom stand dimension Unit: mm (inch)
Nominal size S1 S2 S3
15mm (½”) 19 (0.75) 7.3 (0.29) 11 (0.43)
20mm (¾”) 19 (0.75) 7.3 (0.29) 11 (0.43)
25mm (1”) 19 (0.75) 7.3 (0.29) 11 (0.43)
32mm (1¼”) 30(1.18) 9 (0.35) 15 (0.59)
40mm (1½”) 30(1.18) 9 (0.35) 15 (0.59)
50mm (2”) 30(1.18) 9 (0.35) 15 (0.59)
Applicable Ensat (Reference)
Nominal size Screw size Length
(mm) Material
15mm (½”) M5 10
Brass
20mm (¾”) M5 10
25mm (1”) M5 10
32mm (1¼”) M6 14
40mm (1½”) M6 14
50mm (2”) M6 14
Maker: K.K.V. Corporation
Bottom stand
Ca󲘢󲘡i󲘜󲘛
2-φS2 Depth S3