Installation, Operation and Maintenance Manual
Butterfly Valves Type 75, 75D Electric Actuated Type S 10
Bolt A Bolt B
- The parallelism and axial misalignment of the flange surface should be under the values shown in the
following table to prevent damage the valve. (A failure to observe them can cause destruction due to
stress application to the pipe.)
Unit: mm (inch)
Nom. Size Axial
Misalignment
Parallelism
(a-b)
450-600mm
(18”-24”)
1.5
(0.06”)
1.0
(0.04”)
(8) Support setting procedure
- Do not subject the valve to pump vibrations. (The valve may be damaged.)
- Valves must be supported. (The valve may be damaged by the weight of the actuator if it is unsupported.)
Spanner wrench U-type clamp (with bolt) Rubber sheet
Level installation
Set the stand under the valve.
Spread the rubber sheet on the pipe and secure pipe with
U-type clamp.
Perpendicular installation
Spread the rubber sheet under the actuator, and fix it with the stand.
Spread the rubber sheet on the pipe and secure pipe with
U-type clamp.
Necessary items
Caution
Caution
(Axial misalignment) (Parallelism)