WATER SUPPLIES
13
SUMMARY OF WATER CHEMISTRY ADVICE AFFECTING WARRANTY
The water heater, solar collectors and their components are not suitable for certain water chemistries. Those
chemistries are listed below. If the water heater is connected at any time to a water supply with the following
water chemistry, the Rheem warranty will not cover any resultant faults on the components listed below:
Water Chemistry
Component
Total Dissolved Solids (TDS) > 2500 mg/L
water heater cylinder
Total Dissolved Solids (TDS) not suitable for anode type
water heater cylinder
Saturation Index (SI) > +0.4
(if an expansion control valve is not fitted)
temperature pressure relief valve,
water heater cylinder
-1.0
no warranty applies to a:
temperature pressure relief valve or a
water heater cylinder unless an
expansion control valve is fitted.
SATURATION INDEX (SI)
STORAGE TANKS
WITHIN WARRANTY
SPECIFICATION
SATURATION INDEX
(calculated @ 80°C water temperature)
+0.4 +0.80
very corrosive very scaling
scaling
corrosive
Terms of Use | Privacy Policy | DMCA Policy