Air General Data/Electrical Data
RA13 Series
8
Physical Data
PHYSICAL DATA
Model No. RA1318 RA1324 RA1330 RA1336 RA1342 RA1348 RA1360
Nominal Tonnage 1.5 2.0 2.5 3.0 3.5 4.0 5.0
Valve Connections
Liquid Line O.D. – in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8
Suction Line O.D. – in. 3/4 3/4 3/4 3/4 7/8 7/8 7/8
Refrigerant (R410A) furnished oz.¹ 54 60 72 86 105 106 148
Compressor Type Scroll
Outdoor Coil
Net face area – Outer Coil 5.9 9.1 9.1 12.1 14.2 14.8 18.8
Net face area – Inner Coil ——————
Tube diameter – in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8
Number of rows 1111111
Fins per inch 22 18 22 22 22 22 22
Outdoor Fan
Diameter – in. 20 20 20 20 20 24 26
Number of blades 2233232
Motor hp 1/8 1/8 1/4 1/4 1/8 1/6 1/5
CFM 2040 2325 2795 2900 2465 4145 3870
RPM 1075 1075 1075 1075 1075 850 820
watts 144 137 189 186 176 279 235
Shipping weight – lbs. 127 142 163 164 195 202 235
Operating weight – lbs. 120 135 156 157 188 195 228
Electrical Data
Line Voltage Data (Volts-Phase-Hz) 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60
Maximum overcurrent protection (amps)² 20 25 30 35 40 50 60
Minimum circuit ampacity³ 13 15 18 23 24 29 35
Compressor
Rated load amps 9.7 11.2 12.8 16.7 17.9 21.8 26.4
Locked rotor amps 48 60.8 64 83.9 112 117 134
Condenser Fan Motor
Full load amps 0.7 0.7 1.3 1.3 0.7 1 1.2
Locked rotor amps 1.3 1.3 2.5 2.6 1.3 2.2 2.0
Line Voltage Data (Volts-Phase-Hz) 208/230-3-60 208/230-3-60 208/230-3-60 208/230-3-60
Maximum overcurrent protection (amps)² — — 20 30 30 35
Minimum circuit ampacity³ — — 15 18 19 22
Compressor
Rated load amps 10.4 13.2 13.7 16
Locked rotor amps — — 73 88 83.1 110
Condenser Fan Motor
Full load amps 1.3 0.7 1 1.3
Locked rotor amps 2.6 1.3 2.2 2.0
Line Voltage Data (Volts-Phase-Hz) 480-3-60 480-3-60 480-3-60 480-3-60
Maximum overcurrent protection (amps)² — — 15 15 15 15
Minimum circuit ampacity³ 8 8 9 11
Compressor
Rated load amps 5.8 6.0 6.2 7.8
Locked rotor amps — — 38 44 41 52
Condenser Fan Motor
Full load amps .6 .3 .6 .6
Locked rotor amps — — 2.5 .9 1.6 1.1
¹Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the installation instructions for information about set length and additional
refrigerant charge required.
²HACR type circuit breaker of fuse.
³Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements.