Note: The water heater must be well secured to the wall or frame using two fasteners each at the top and
bottom of the unit (refer to page 23 for mounting hole positions and weight of the water heater). Use the
screws provided only if they are suitable for the wall or frame type. Otherwise select and use alternative
fasteners suitable for the application. The fasteners must be capable of bearing the full weight of the water
heater so it may not work loose nor impose any load on the gas and water pipe work connected to the water
heater. Refer to the fastener manufacturer’s information and recommendations for the type of fastener to use
for the wall or frame type and load bearing requirements.
Alternatively the water heater can be recessed into a wall (refer to “Recess Installation” on page 17).
For a single water heater installation, refer to the typical installation diagram on page 24.
For a multiple water heater installation, refer to Multiple Installations on page 28 and the typical installation
diagram on page 29.
The water heater must not be installed in an area with a corrosive atmosphere where chemicals are stored or
where aerosol propellants are released. Remember the air may be safe to breathe, but when it goes through
a flame, chemical changes take place which may attack the water heater.
A secondary flue is not required. The water heater must not be installed indoors or in a confined space.
The water heater must be located to ensure that the location of the flue terminal complies with the
requirements of AS 5601 or AS/NZS 5601.1, as applicable under local regulations. As a guide the following
requirements are extracted from the Gas Installations Standard. The distances are measured along the wall
behind the water heater.
At least 300 mm between the top of the flue terminal
and the eaves.
At least 500 mm between the flue terminal and the
edge of any opening into the building, such as an
openable door or window, measured horizontally*.
At least 1500 mm between the top of the flue terminal
and the edge of any opening into the building, such as
an openable window, measured vertically.
At least 300 mm between the flue terminal and a
return wall or external corner, measured horizontally*.
At least 1500 mm between the flue terminal and any
opening into a building, in the direction of the flue
discharge.
At least 500 mm between the flue terminal and a fence, wall or other obstruction, in the direction of the
flue discharge.
Note: * If these horizontal distances cannot be achieved, AS/NZS 5601.1 states an equivalent horizontal
distance measured diagonally from the nearest discharge point of the flue terminal to the opening may be
deemed to comply. Check with the local regulator.
Note: Two of this model water heater can be installed side by side with minimal clearance between them.
The AGA has approved the installation of two of this model water heater with an exemption from the 300 mm
minimum clearance requirements between flue terminals, as stated in AS/NZS 5601, clause 5.13.6.5 and
AS/NZS 5601.1, clause 6.9.3.