Planning and Installation Guide Chapter 14: Site Requirements and Preparation
192
Refer to Appendix H for a information on all ShoreGear switches, including capabilities,
connectors, and LED behavior.
14.3 Voice Switch Requirements
This section includes requirements for mounting the ShoreGear voice switches, along with
other switch-related requirements and specifications.
14.3.1 Physical Requirements
The ShoreGear voice switches are designed to be mounted in a standard 19-inch rack.
Table 14-2 shows the specifications for each voice switch. For more information refer to the
, included with each ShoreGear voice switch.
Table 14-3 shows the latest hardware line, designed to increase port density.
14.3.2 Input Power
For backup purposes, ShoreTel recommends that all ShoreGear voice switches and the
ShoreWare server be connected to an uninterruptable power supply (UPS). This ensures
that telephone service will continue in the event of a power interruption.
Table 14-4 shows the power requirements for the full-width ShoreGear voice switches.
Table 14-5 shows the power requirements for the half-width ShoreGear voice switches.
Parameter
ShoreGear 120
ShoreGear 60
ShoreGear 40
ShoreGear T1
ShoreGear E1
Dimensions (H x W x D) 1.72” x 17.16” x 14.28 “
43.68 x 435.86 x 362.71 mm
1.72” x 17.16” x 14.28 “
43.68 x 435.86 x 362.71 mm
Rack mount units 1 RU 1 RU
Mounting position Front, Center Front, Center
Weight 9 lbs
4.08 kg
8 lbs
3.62 kg
Maximum stacked per shelf 3 switches 3 switches
Table 14-2 ShoreGear Voice Switch Physical Specifications
Parameter Dimension
Dimensions (H x W x D) 1.69” x 8.39” x 14.28 “
43 x 213 x 378 mm
Rack mount units 1 RU
Mounting position Front, Center
Weight 5.3 lbs
2.4 kg
Maximum stacked per shelf 6 switches
Table 14-3 Half-Width ShoreGear Voice Switch Physical Specifications
Terms of Use | Privacy Policy | DMCA Policy